16th Meeting: Geneva, October 2019 2019-10-04 17:52
Non-CE4: Neighboring locations for CIIP
Abstract
This contribution proposes to change the derivation of neighboring locations used for CIIP weight determination. CIIP (Combined inter merge and intra prediction) refers two neighboring locations to determine the weight for the combination of the inter prediction signal and the intra prediction signal. The two neighboring locations are left and above of the current block, but for the color format other than 4:2:0, the derived location in the specification indicates a non-adjacent location for chroma components. The proposed change fixes the specification text on neighboring locations to represent left and above locations for all color formats.
JVET-P0595 Non-CE4: Neighboring locations for CIIP [G. Ko, D. Kim, J. Jung, J. Son, J. Kwak (WILUS)]
References:
JVET-O2001
Decisions
JVET-P0595 Non-CE4: Neighboring locations for CIIP [G. Ko, D. Kim, J. Jung, J. Son, J. Kwak (WILUS)]
Citation