31st Meeting: Geneva, CH, July 2023 2023-07-11 09:53
EE2-3.7 RPR with new filters for scale factor 1.25x and 1.33x
Abstract
This input document reports the results of applying new RPR filters for scale factors 1.25x and 1.33x, which is tested in EE2-3.7a and EE2-3.7b. New filters are used for luma, chroma and affine. The same filters are used for both 1.25x and 1.33x. The reported average BD-Rate difference (Y/U/V) for EE2-3.7a (1.25x) is -0.77%/-0.64%-0.55% for PSNR1 and -0.76%/-0.40%-0.40% for PSNR2. The reported average BD-Rate difference (Y/U/V) for EE2-3.7b is -2.09%/-1.24%-1.21% for PSNR1 and -2.02%/-1.35%-1.27% for PSNR2. In the first version of this document the average numbers for EE2-3.7b (1.33x) did not include BasketballDrive and BQTerrace, as these results were still awaited. These average numbers for EE2-3.7b (1.33x) have been updated in the second version of this document to include all sequences.
JVET-AE0150 EE2-3.7 RPR with new filters for scale factor 1.25x and 1.33x [J. Samuelsson-Allendes, S. Deshpande (Sharp)]
Decisions
JVET-AE0150 EE2-3.7 RPR with new filters for scale factor 1.25x and 1.33x [J. Samuelsson-Allendes, S. Deshpande (Sharp)]
Citation